Setting outputs

Connecting outputs to the engine control unit

The OUT1 and OUT2 outputs have three terminals.

The NC terminals of the OUT outputs have a normally closed contact towards COM, while the NO terminals have an normally open contact (break) towards COM.

The S2 switch
2. In case of DUAL OUTPUT mode (S2 switch in “ON” position)

If the motor controller has two separate control inputs for opening and closing, set the S2 switch to the upper “ON” position . In this control mode, the OUT1 output provides the control pulse for opening, and OUT2 for closing.

2. In case of SINGLE OUTPUT mode (S2 switch in “OFF” position)

If the motor controller has only one control input , set the S2 switch to the lower “OFF” position . In this control mode, the OUT1 output provides the control pulse for both opening and closing, and the OUT2 output remains activated for each control for a period of time that can be set in the mobile application. The OUT2 output can be used with motor controllers that require a longer control pulse for opening / holding open, but can also be suitable for controlling gate lighting.

Setting scheme of the "Operating mode" switches

Would you like to know more about setting up outputs?

Read the frequently asked questions below. In our experience, you will find a solution to 95% of the problems, but if not, our Technical Support colleagues are always at your disposal.

Go to the FAQ!

Do you have any further questions?

TELL Security Systems Trading and Service Ltd.

Address: 4034 Debrecen Vágóhíd Street 2.
Phone: +36 52 530 130
Technical support: +36 1 533 31 20

If you have any questions about our products or services, or would like to initiate a collaboration, please contact us with confidence. Our colleagues are at your disposal and will be happy to help with any needs or problems that arise.

* By sending this message, I accept and consider the data processing policy to be binding.